- Federal Specification HH-I-1972/GEN has been cancelled
- ASTM C 1289, Type V
- Miami-Dade County, Florida Product Control No. 00-0208.04 (with 19/32" plywood)
- State of California, License #TC 1231
- IBC, NBC, UBC and SBC Sections on Foam Insulation (Chapter 26).
- FHA minumum property requirements
- ARMA insulated deck requirements
- APA/TECO rated OSB nailable surface
FM Standard 4450/4470 Approval (1-105, 1-90, 1-60) ACFoam CrossVent RB Insulation is approved for Class 1 insulated roof deck construction. Refer to FM Approval Guide for details.
UL Standard 1256 Classification Insulated metal deck construction assemblies - Construction #120 and #123.
UL Standard 790 Classification (ASTM E108) For use with Class A, B or C shingles, metal or tile roof coverings.
UL Standard 263 Fire Resistance Classification (ASTM E119) Some classifications for fire resistance are P225, P230, P259, P508, P510, P514, P701, P717, P719, P723, P728, P732, P734, P739, P801, P815, and P819. See UL Fire Resistance Directory.
CrossVent RB is covered by one or more claims of Patent #5,433,050.
Spec this Product
Net Free Area of Ventilation Per Linear Foot
| ACFoamCrossVent and CrossVent RB have been designed for use over sloped unventilated roof decks. Slopes must be appropriate for the type of roof system specified. The primary purpose of CrossVent and CrossVent RB is to provide a thermally efficient insulation with uniform cross venting that promotes air circulation required by many shingle manufacturers.CrossVent and CrossVent RB allow heat to dissipate while providing a nailable surface and efficient insulation in a one-step labor saving process. Note: Ventilation design is solely the responsibility of the project designer. Designer should consider size of air space,ventilation capabilities of soffit and ridge vents,and length of run,among possible considerations. Atlas recommends a staggered double-layer of ACFoam-II and CrossVent or CrossVent RB for additional energy savings.
|
In response to valid concerns of building designers regarding thermal efficiency of roof assemblies and the long-term insulating value of roof insulation, Atlas offers a 20-year, limited thermal warranty. The "ACFoam" Limited Warranty places Atlas ACFoam products above all others and supports the building owner, designer and contractor by backing up thermal performance. This warranty is available to the building owner at the time the building is completed and is transferable to any subsequent owner for the duration of the 20-year period. 20 Year Limited Warranty
| Atlas Roofing CrossVent RB General Installation Instructions
Atlas recommends a staggered double layer application of ACFoam-II as the first layer and CrossVent or CrossVent RB as the top layer.This application will improve thermal performance and limit moisture and airflow through the roof system.Atlas CrossVent or CrossVent RB should be installed directly over the vapor/air retarder that has been applied over the approved substrate. CrossVent or CrossVent RB should be installed with the 8 ft.dimension parallel to the eave and with the vent spacer strips running up the slope of the roof. CrossVent or CrossVent RB shall be fastened directly through the vent spacer strips in accordance with fastening patterns contained in the Atlas publication, Guide Details (Current Edition) for Nail Base and CrossVent Insulation.
Complete Instructions
|
Storage/Precautions: Factory-applied packaging is intended only for protection during transit. When stored outdoors or on the job site, packages should be stacked on pallets at least four inches above ground level and completely covered with a weatherproof covering such as a tarpaulin. The temporary factory-applied packaging should be slit or removed to prevent accumulation of condensation. Roof insulation which has become wet or damaged should be removed and replaced with solid, dry insulation.
Warning! Do Not Leave Exposed: This product is a polyiso organic plastic foam and will burn if exposed to an ignition source of sufficient heat and intensity, or open flame, such as a welder´s torch. Like other organic materials, this product will release smoke if ignited. Do not apply flame directly to ACFoam roof insulations. This product should be used only in strict accordance with Atlas recommended uses and application instructions.
| Camp Hill
East Moline
Northglenn
LaGrange
Diboll
Phoenix
Toronto
Sales Offices
|