ACFoam Nail Base Insulation is a thermally efficient polyiso insulation board bonded to 7/16" APA/TECO rated OSB on the top side and glass fiber reinforced felt facer on the bottom. ACFoam¨ Nail Base Insulation provides the desirable benefits of both a nailable surface and insulation making installation an easy one-step labor saving process. This product is made to order in 4´ x 8´ (1220mm x 2440mm) size panels and in nominal thicknesses of 1.5" and 4.5". Other thicknesses are available on special order.

Click Here for Guide Details & Fastening Patterns

In 1998, years ahead of the Environmental Protection Agency timetable for eliminating HCFCs (hydrochlorofluorocarbons), Atlas introduced a line of ACFoam Products that are environmentally sensitive and available for virtually every type of construction system. Through a patented hydrocarbon blowing technology called ACUltra, Atlas began the phaseout of HCFCs in the manufacturing of foam insulation and anticipates the complete removal of HCFCs from all Atlas foam products within the next year.

 Long Term Thermal Resistance (LTTR) Values & Thicknesses

 Typical Physical Properties (Foam Portion)

 CODES & COMPLIANCES

  • Federal Specification HH-I-1972/GEN has been cancelled
  • ASTM C 1289, Type V
  • Miami-Dade County, Florida Product Control No. 00-0208.04 (with 19/32" plywood)
  • State of California, License #TC 1231
  • IBC, NBC, UBC and SBC Sections on Foam Insulation (Chapter 26). 
  • FHA minumum property requirements
  • ARMA insulated deck requirements
  • APA/TECO rated OSB nailable surface

FM Standard 4450/4470 Approval (1-105, 1-90, 1-60)
ACFoam Nailbase Insulation is approved for Class 1 insulated roof deck construction. Refer to FM Approval Guide for details.

UL Standard 1256 Classification
Insulated metal deck construction assemblies - Construction #120 and #123.

UL Standard 790 Classification (ASTM E108)
For use with Class A, B or C shingles, metal or tile roof coverings.

UL Standard 263 Fire Resistance Classification (ASTM E119)
Some classifications for fire resistance are P225, P230, P259, P508, P510, P514, P701, P717, P719, P723, P728, P732, P734, P739, P801, P815, and P819. See UL Fire Resistance Directory.


Spec this Product
 

 RECOMMENDED USES

ACFoam Nail Base Insulation is typically specified for use over solid wood and metal decks having a slope of a minimum 1/4" per foot. Slopes must be appropriate for the type of roof system specified. The OSB provides an excellent base for nailing non-asphaltic shingles. It is especially efficient as a component over cathedral ceilings in log homes, conventional housing, churches and athletic auditoriums. Additionally, ACFoam Nail Base Insulation may be installed under metal roof systems and over metal decks minimum 22 gauge or heavier. This product should be used only in strict accordance with Atlas recommended uses and application instructions. Atlas recommends the use of vapor retarder for all projects except in extreme cooling climates. However, determining the need for and location of the vapor retarder remains solely the responsibility of the architect, engineer or design professional.


 
 WARRANTY

In response to valid concerns of building designers regarding thermal efficiency of roof assemblies and the long-term insulating value of roof insulation, Atlas offers a 20-year, limited thermal warranty. The "ACFoam" Limited Warranty places Atlas ACFoam products above all others and supports the building owner, designer and contractor by backing up thermal performance. This warranty is available to the building owner at the time the building is completed and is transferable to any subsequent owner for the duration of the 20-year period.

20 Year Limited Warranty
 

 INSTALLATION

Atlas Nail Base should be installed directly over the vapor retarder that has been applied over the deck. Atlas requires the use of Atlas Nail Base fasteners. Refer to Atlas Guide Details for Nail Base and Vented-R Insulation for fastening patterns and other application recommendations. Additional installation recommendations for Atlas Nail Base Fasteners are as follows:
 
Complete Instructions
 

 STORAGE

Storage/Precautions: Factory-applied packaging is intended only for protection during transit. When stored outdoors or on the job site, packages should be stacked on pallets at least four inches above ground level and completely covered with a weatherproof covering such as a tarpaulin. The temporary factory-applied packaging should be slit or removed to prevent accumulation of condensation. Roof insulation which has become wet or damaged should be removed and replaced with solid, dry insulation.

Warning! Do Not Leave Exposed: This product is a polyiso organic plastic foam and will burn if exposed to an ignition source of sufficient heat and intensity, or open flame, such as a welder´s torch. Like other organic materials, this product will release smoke if ignited. Do not apply flame directly to ACFoam roof insulations. This product should be used only in strict accordance with Atlas recommended uses and application instructions.


 
 SALES OFFICES

Camp Hill

East Moline

Northglenn

LaGrange

Diboll

Phoenix

Toronto

Sales Offices

[TOP]



Features & Benefits

ACUltra Technology means ZERO HCFC´s

Excellent
R-values reduce energy demand

Superior performance in fire tests

Approved for installation directly on the roof deck without a thermal barrier

Cost-effective, environmentally friendly solution for any roof

Case Studies

Contractor’s Prayers Answered On New Atlanta Church