Typical Physical Properties (Foam Portion)
| Property | Test Method | Typical Results |
| Dimensional Stability (Length & Width | ASTM D 2126 | <2% |
| Compressive Strength (10% Deformation) | ASTM D 1621 | 20 psi (138 kPa) or 25 psi (172 kPa) |
| Water Absorption | ASTM C 209, ASTM D 2842 | <1% <3.5% |
| Moisture Vapor Transmission | ASTM E 96 | <1.0 perm (85.0ng/ (Pa•s•m2)) |
| Product Density | ASTM D 1622 | Nominal 2.0 pcf (32.04 kg/m3) |
| Flame Spread | ASTM E 84 (Full 10 min. Test) | 40-60* |
| Smoke Developed | ASTM E 84 (Full 10 min. Test) | 50-170* |
| Tensile Strength | ASTM D 1623 | >730 psf (35 kPa) |
| Service Temperature | - | -40 to 200° F** |
|
*The numerical ratings as determined by ASTM Test Method E 84 are not intended to reflect hazards presented by this or any other material under actual fire conditions. A flame spread index of 75 or less and smoke development of 450 or less meet code requirements regarding flame spread and smoke development for foam plastic roof insulation. However, the codes exempt foam plastic insulation when used in roof deck constructions that comply as an assembly with FM 4450 or UL 1256 (see IBC, NBC, UBC, and SBC Sections on Foam Plastic Insulation (Chapter 26). Smoke development does not apply to roofing. **ASTM C 1289 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board. The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. This data is offered as a service to our customers and is subject to change. For questions about data, please contact Atlas's technical department. |
||
| Loading News Ticker... |